Find great deals for Hörmann Universaladapterplatine UAP 1. Shop with confidence on eBay!. For Hörmann door, Type: SupraMatic, Rotamatic / P / PL from year 09/ and LineaMatic built from 10/ – About for direction selection (up / stop / close). For inputs to Hormann: does it mean that I have to run 6 wires for this section from Loxone to Hormann? Or is it possible to reuse the wire for

Author: Shazshura Vujinn
Country: Fiji
Language: English (Spanish)
Genre: Career
Published (Last): 7 August 2004
Pages: 280
PDF File Size: 5.44 Mb
ePub File Size: 16.95 Mb
ISBN: 624-3-81660-618-1
Downloads: 99522
Price: Free* [*Free Regsitration Required]
Uploader: Zulkijin

Burglar alarm As you can see the only status bit set, is from the second byte and means reversing according to the patent which makes no sense to me. I am an electronics amateur and can’t figure out based on the schematic below if that is correct?

Here’s what I got using the USB converter with the door closed idling:. In my case the UAP1 answers: To dig deaper into the protocoll I need more data. By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies.

These horkann the messages I was able to make sense of so far. As you can see the only status bit set, is from the second byte and means reversing according to hormsnn patent which makes no sense to me.

It decrements this address and scans the entire bus. I tried some CRC brute force attempts but without success. Not specified in the patent Thanks for looking into this! Bottom side of the circuit hirmann That tells me that it appears your UAP will not allow for the individual movements that you are looking to achieve. The only things I get from what is stated is that if you press to open – you press the button again to stop it not a true move up move down motion.

  AUTOSTRETCHING EVJENTH PDF

I expected a iap1 simple protocoll where no comunication happens until the UAP1 gets triggered by a switch, but I was more than wrong.

For that to work I needed to buy a UAP horkann adapter, meant for uses like these and connect it to my Loxone miniserver.

To control the hromann via a home automation system you have several options: The changed partial opening position is saved. I used the CRC calculator at http: To supply the board with 24VDC, which normally comes in via the RJ12 connector, I simply used the terminals taht normally connect the switches. Hormann garage door opener automation with Loxone Ask Question. Drives at least the three relais, maybe more.

That way I’m able to trace the bus in realtime without the need to leave the house It’s pretty cold outside at this time of the year. Speak directly to the motor and get the signals directly onto the homeautomation system. Learning button assignment Bit 7: I found this guidewhich made the setup easier and I’ve setup everything accordingly. Dominik Hadl 51 4. Any help would be greatly appreciated. But at least I can connect to GND there.

Ken 4, 1 4 This is how far i got until now.

Sign up using Facebook. Here’s what I got using the USB converter with the door closed idling: The remotes require a 2 second press to avoid accidental presses, have you tried making your pulse longer?

It seems that this must hrmann when the UAP1 is connected to the motor.

Unfortunately no other communication is happening when I trigger a “close door” for example. Light on Bit 1: Connect potential free contacts directly to the motor. Not much to see here, just that all pins of the 6-pin RJ12 sockets are directly conected to each other.

  JANINE BENYUS BIOMIMICRY PDF

Hörmann Universaladapterplatine UAP 1 | Smolka Tor- und Antriebstechnik Berlin Online Shop

Sign up using Email and Password. According to the Guide you posted The UAP enables you to control the light of the supramatic open the garage door close the garage door stop the garage door check whether the door is totally closed or totally open, light status? Unfortunately the patent doesn’t say anything about the device codes. Sign up or log in Sign up using Google. To control the door via a home automation system you have several options:.

But how can I tell who is sending which bytes!? RX When the board is powered while the logic analyzer is collecting data, we see these bytes comming in: Why it doesnt scan the adresses down to ? I hoped to find the signals there as well but it turned out that is not the case.

Reverse engeneering the Hörmann UAP1 protocoll

Post Your Answer Discard By clicking “Post Your Answer”, you acknowledge that you have read hormannn updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies. A message is always formed like this: Hardware Top side of the circuit board: At startup the Master scans the bus for devices. Press the PRG button until the decimal point next to the menu number is illuminated. I’ll try to extend this artcle or write a followup in the future.

If the selected height is too low, a 2-digit number starting with 1 will appear with a flashing decimal point see section